Each of the "Default Led Mode" settings change how the reader responds base on the readers current setting and/or what is being requested.  For example "Use Default LED Table 1", if you unlock the portal, the reader light will go green for 2.9 seconds and then change to light off for 0.1 seconds.  Below you can find the standard settings from Mercury.  

Note: If your reader does not support "Off" or "Amber", the color "Red" will be used.

Definitions

Name Description
LED ID Reader LED/buzzer function ID (1 to 8, or 11 to 16).  The function IDs correspond to the ACR mode, or the state of the door cycle. 
On Color Color to display during on_time
Off Color Color to display during off_time
On Time Duration to display on_color (.1sec/tick) 
Off Time Duration to display off_color (.1sec/tick) 
Repeat Count If transient, the number of times to repeat cycle.  Valid values are 1 to 255.
Beep Count If transient, the number of times to beep.  Valid values are 0 to 15. 
Description Text Line 1 Text index of  LCD Text specified in Command 123 for Line1 (top)   (Zero to stay with current) 
Description Text Line 2 Text index of  LCD Text specified in Command 123 for Line2 (lower)   (Zero to stay with current) 
ACR Mode or State of Door The Reader Mode or state of the door.  Ex. Unlocked, Locked, Card Only...
 
 

Default Setting for LED Mode Table 1

Led ID On Color Off Color On Time Off Time Repeat Count Beep Count Description Text Line 1 Description Text Line 2 ACR Mode or State of Door
1 Red Off 29 1 0 0 Locked Clock Off
2 Green Off 29 1 0 0 Unlocked Clock Unlocked
3 Red Off 29 1 0 0 Locked Clock Exit OK
4 Red Off 1 29 0 0 Ready Clock Facility Code Only
5 Red Off 1 29 0 0 Ready Clock Card Only
6 Green Off 1 29 0 0 Enter PIN ?. PIN Only
7 Red Off 1 29 0 0 Ready Clock Card & Pin
8 Green Off 1 29 0 0 Ready Clock PIN or Card
11 Red Off 2 2 5 3 Invalid Clock Deny
12 Green Off 2 2 7 1 Valid Clock Admit
13 Green Off 1 14 0 2 Enter Command ?. User Command
14 Green Red 1 4 6 2 Next Request ?. 2nd User (Card)
15 Green Red 4 1 25 2 Enter Next Pin ?. 2nd User (PIN)
16 Green Red 1 4 6 2 ... Clock Wait

 

Default Setting for LED Mode Table 2

Led ID On Color Off Color On Time Off Time Repeat Count Beep Count Description Text Line 1 Description Text Line 2 ACR Mode or State of Door
1 Red Off 29 1 0 0 Locked Clock Off
2 Green Off 29 1 0 0

Unlocked

Clock Unlocked
3 Red Off 29 1 0 0 Locked Clock Exit OK
4 Red Off 24 1 0 0 Ready Clock Facility Code Only
5 Red Off 24 1 0 0 Ready Clock Card Only
6 Red Off 24 1 0 0 Enter PIN ?. PIN Only
7 Red Off 24 1 0 0 Ready Clock Card & Pin
8 Red Off 24 1 0 0 Ready Clock PIN or Card
11 Red Off 2 2 5 3 Invalid Clock Deny
12 Green Off 2 2 7 1 Valid Clock Admit
13 Green Off 1 14 0 2 Enter Command ?. User Command
14 Green Red 1 4 6 2 Next Request Clock 2nd User (Card)
15 Green Red 4 1 25 2 Enter Next Pin ?. 2nd User (PIN)
16 Green Red 1 4 6 2 ... Clock Wait

Default Setting for LED Mode Table 3

Led ID On Color Off Color On Time Off Time Repeat Count Beep Count Description Text Line 1 Description Text Line 2 ACR Mode or State of Door
1 Red Off 29 1 0 0 Locked Clock Off
2 Green Off 29 1 0 0

Unlocked

Clock Unlocked
3 Green Off 29 1 0 0 Locked Clock Exit OK
4 Green Off 29 1 0 0 Ready Clock Facility Code Only
5 Green Off 29 1 0 0 Ready Clock Card Only
6 Green Off 29 1 0 0 Enter PIN ?. PIN Only
7 Green Off 29 1 0 0 Ready Clock Card & Pin
8 Green Off 29 1 0 0 Ready Clock PIN or Card
11 Red Off 2 2 5 3 Invalid Clock Deny
12 Green Off 2 2 7 1 Valid Clock Admit
13 Green Off 1 14 0 2 Enter Command ?. User Command
14 Green Red 1 4 6 2 Next Request Clock 2nd User (Card)
15 Green Red 4 1 25 2 Enter Next Pin ?. 2nd User (PIN)
16 Green Red 1 4 6 2 ... Clock Wait