PIM400-485
Overview
The PIM400 is used to connect the Mercury hardware to one or more wireless Schlage locks via a RS485 connection.
Click to view: PIM_Intelligent_Controller_Data_Sheet.pdf
Features
- 900 MHz spread spectrum RF technology for long range, reliable communications
- Automatic linking to remote wireless access points with 10 channel frequencies to select from enables easy commissioning
- AES-128 bit encrypted spread spectrum transmissions
- 5 visual indicators to quickly pinpoint and display status
Connecting the PIM400 to the Controller
- Set the 2 | 4 wire (P5) to 2 wire setting by shorting RA- (Pin 1) to TA-(Pin 2) and TB+(Pin 3) to RB+(Pin 4) using two jumpers.
- Attach the white wire(TR+) from the RS485 bus to TDA-.
- Attach the green wire(TR-) from the RS485 bus to TDB+.
- To power the PIM400 connect 12 - 24 VDC(P2) to power.
Couple the PIM400 to the HHD
- Remove the cover of the PIM400.
- Open the Schlage Utility application on the HHD( HandHeld Device).
- Click SUS Options.
- Then click Connection Type and ensure the HHD is set to USB Connection.
- Connect the HHD and the PIM400 via the provided USB cable.
- Return to SUS Options and click Device Option on the HHD.
- On the PIM400 press and hold the Link 1 Button (SW1).
- Press the Link 2 Button (SW2) three times.
- On the HHD, select Couple HHD to Device.
- If the success message appears the HHD is now paired with the PIM400.
- Note: This will only have to be done once per PIM400 as it remembers the password for the device.
Putting the PIM400 into Link Mode
- Ensure the HHD is coupled to the PIM400.
- Connect the HHD to the PIM400via the USB
- If the PIM400-485 shows up on the HHD then the device is couple.
- If you do not see the PIM400 follow our directions to couple the two devices.
- Select Device Options.
- Next, select PIM Properties.
- Click the Link tab.
- Select the Door you wish to pair and press the Link button.
- You may now pair the PIM and the door.
- The PIM will remain in Link Mode for 30 minutes or until the door is paired.