Skip to main content
BluINFO

Relay Elevator Floor ID Relay Kits

Overview

Article type: Datasheet
  • BluCHIP EMR-16RELAY-FID (753-4000)The BluCHIP EMR-16RELAY-FID is a Relay Elevator System I/O that supports up to 16 floor stops with Floor ID. The Floor ID feature allows the security system to capture elevator controller feedback of the floor selected by the user. The kit is designed to be installed in an elevator machine room and works in conjunction with an EMR Controller kit. The kit is configured with space to add backup battery and utilizes an FPO power supply to generate 24VDC and a B100 to generate 12VDC. It includes one
  • BluCHIP EMR-32RELAY-FID (753-4100)The BluCHIP EMR-32RELAY-FID is a Relay Elevator System I/O that supports up to 32 floor stops with Floor ID. The Floor ID feature allows the security system to capture elevator controller feedback of the floor selected by the user. The kit is designed to be installed in an elevator machine room and works in conjunction with an EMR Controller kit. The kit is configured with space to add backup battery and utilizes an FPO power supply to generate 24VDC and a B100 to generate 12VDC. It includes two
  • BluCHIP EMR-48RELAY-FID (753-4200)The BluCHIP EMR-48RELAY-FID is a Relay Elevator System I/O that supports up to 48 floor stops with Floor ID. The Floor ID feature allows the security system to capture elevator controller feedback of the floor selected by the user. The kit is designed to be installed in an elevator machine room and works in conjunction with an EMR Controller kit. The kit is configured with space to add backup battery and utilizes an FPO power supply to generate 24VDC and a B100 to generate 12VDC. It includes thr
  • BluCHIP EMR-64RELAY-FID (753-4300)The BluCHIP EMR-64RELAY-FID is a Relay Elevator System I/O that supports up to 64 floor stops with Floor ID. The Floor ID feature allows the security system to capture elevator controller feedback of the floor selected by the user. The kit is designed to be installed in an elevator machine room and works in conjunction with an EMR Controller kit. The kit is configured with space to add backup battery and utilizes an FPO power supply to generate 24VDC and a B100 to generate 12VDC. It includes fou
  • BluCHIP EMR-80RELAY-FID (753-4400)The BluCHIP EMR-80RELAY-FID is a relay elevator system I/O that supports up to 80 floor stops with Floor ID. The Floor ID feature allows the security system to capture elevator controller feedback of the floor selected by the user. The kit is designed to be installed in an elevator machine room and works in conjunction with an EMR Controller kit. The kit is configured with space to add backup battery and utilizes an FPO power supply to generate 24VDC and a B100 to generate 12VDC. It includes fiv
  • BluCHIP EMR-96RELAY-FID (753-4500)The BluCHIP EMR-96RELAY-FID is a Relay Elevator System I/O that supports up to 96 floor stops with Floor ID. The Floor ID feature allows the security system to capture elevator controller feedback of the floor selected by the user. The kit is designed to be installed in an elevator machine room and works in conjunction with an EMR Controller kit. The kit is configured with space to add backup battery and utilizes an FPO power supply to generate 24VDC and a B100 to generate 12VDC. It includes six
  • BluCHIP EMR-112RELAY-FID (753-4600)The BluCHIP EMR-112RELAY-FID is a Relay Elevator System I/O that supports up to 112 floor stops with Floor ID. The Floor ID feature allows the security system to capture elevator controller feedback of the floor selected by the user. The kit is designed to be installed in an elevator machine room and works in conjunction with an EMR Controller kit. The kit is configured with space to add backup battery and utilizes an FPO power supply to generate 24VDC and a B100 to generate 12VDC. It includes s
  • BluCHIP EMR-128RELAY-FID (753-4700)The BluCHIP EMR-128RELAY-FID is a Relay Elevator System I/O that supports up to 128 floor stops with Floor ID. The Floor ID feature allows the security system to capture elevator controller feedback of the floor selected by the user. The kit is designed to be installed in an elevator machine room and works in conjunction with an EMR Controller kit. The kit is configured with space to add backup battery and utilizes an FPO power supply to generate 24VDC and a B100 to generate 12VDC. It includes e