Overview

This article details all of the actions that can be taken when a rule is successful.  A rule can do many things like send an email, change a relay, or open/close a portal.

Then Actions

The resulting action from a Rule can vary greatly from one to another. The list below is a quick guide to help you choose the desired output of your Rule.  

Then Actions Description
Control Point - Activate This will activate one or more Control Points.
Control Point - Deactivate This will deactivate one or more Control Points
Control Point - Pulse This will pulse the control point.  The pulse uses the "Default Pulse Seconds" setting in the Control Points configuration.  See Edit a Control Point to see how to change the length of the pulse.
Create Logical Alarm This will cause a special custom Alarm Event, that will appear on the Real-time Events screen.  This event will stay in the alarm screen until acknowledged.  This makes sure that a rule is responded to and you want to know who responded.
Do nothing - wait for complex rule Use this Action when you want to defer the resulting action to a Complex Rule. This is helpful when you are using multiple Simple Rules as conditions of a Complex Rule. 
Execute Procedure (In Panel) This action will call a system Procedure. See Procedures,  Note: A trigger will be selected, but the trigger does not need to be successful.  The rule is overriding the trigger and calling the procedure and the comments its includes.  This is great when you want a rule to have multiple actions that are used by other rules.
Floor (stop) - Card Access This sets one or more Floors to Card Access.
Floor (stop) - Lock This will lock one or more Floors.
Floor (stop) - On Schedule This places one or more Floors "On Schedule".
Floor (stop) - Release This releases one or more Floors.
Floor (stop) - Unlock This unlock one or more Floors.
Floor Matrix - Disable Free Access This will disable the ability to select a Floor using a Destination Dispatch System.
Floor Matrix - Enable Free Access This will enable the ability to select a Floor using a Destination Dispatch System.
IPS Group - Arm Instantly This arms an IPS Group immediately. 
IPS Group - Disarm This disarms an IPS Group.
IPS Point - Bypass This bypasses an IPS Point allowing an IPS Group to be armed. 
IPS Point - Disable This disables an IPS Point. 
IPS Point - Enable This enables an IPS Point.
LSP - Cycle Power This will cause the LifeSafety Power equipment to cycle it's power. This requires a properly configured NL2 or NL4.
Portal - Card Access This sets one or more Portals to Card Access.
Portal - Lock This locks one or more Portals.
Portal - On Schedule This return one or more Portals to normal operating parameters. 
Portal - Release This releases one or more Portals.
Portal - Unlock This sets one or more Portal to unlock. 
Send Email This sends an email to a Distribution List or a single person.
Send Text Message This sends an SMS text message to a Distribution List or a single person.
Trigger Alarm Point This causes an IPS Point to enter an alarm state. 

 