IPS Group States
BluSKY URL: https://blusky.blub0x.com/en-US/MercuryIPSGroup
Overview
An Intrusion Prevention System(IPS) Group is used to organize individual IPS Points into an easily managed group. This article provides a resources for understanding the different states of the IPS Group.
An IPS Group will be in one of the following states:
IPS Group State | Description |
---|---|
Disarmed | Neither an interior nor an exterior point will cause an alarm if it is activated. The IPS group may be armed only if none of the perimeter points are active. |
Fault | The system is disarmed and points are in supervisory fault or offline. |
Armed Away | All points will cause an alarm after the exit or entry delays expire |
Armed Stay | Only the Perimeter points will cause an alarm if activated. |
Armed Instant | Perimeter points will cause an alarm if activated. Interior points will not cause an alarm if activated. |
Entry Delay | The system was armed and a point for which the entry delay parameter is set has been activated. |
Exit Delay | The system has been armed and an exit delay is in progress. |
Alarm | The system is in alarm and the alarm has not been canceled. |
Alarm Canceled | The system has an active alarm, the alarm has been silenced and alarm history is available. |