BluCHIP 4502-4R/16I/10O-E2M (750-4601)
Mercury LP4502 Four Reader/ Sixteen Input/ Ten Output System for Four Doors
The BluCHIP 4502-4R/16I/10O-E2M is a unified Four Reader/ Sixteen Input/Ten Output System for Four Doors. The kit is configured with space to add backup battery and utilizes an FPO power supply to generate 12 or 24VDC. It includes a Mercury LP4502 and a Mercury MR52-S3 board, a locking four door enclosure with tamper, power supply and wiring speed kit. Remote management and reporting of power supply and battery health are available through BluSKY Power Diagnostics.

System Features
FPO offline power supply
- 120 or 230 VAC input
- 12 and 24 VDC outputs
- On board Fire Alarm Interface
- Continuous and resettable DC
Distributed output module
- Four, controlled fused at 3A each
- Eight, auxiliary Class II P limited at 2.5A each
Expansion options
- Increased power, multiple voltages
- Additional distribution outputs
- Power management
Enclosure Features
Labor saving design
- Unified power and security in one enclosure
- Pre-wired power section
- Removable backplate simplifies installs
- Speed kit is included for power and data wiring
Additional benefits
- Wire management room
- 4.5” enclosure depth fits battery set
- Tamper switch, lock, dual key set standard
- Mounting hardware for access boards included
Specifications
Input Power:
- Input 120/230VAC 50/60Hz | 100 Watts
- Overload and short circuit protection
- Over temperature protection
- Polarized AC power supply disconnect
- 75W Total Output Power | 12VDC/6A or 24VDC/3A
- FPO Board Outputs: Continuous (DC1), Resettable (DC2)
- 120mV Output Voltage Ripple | System Efficiency: 85% | System BTU Rating: 33 BTU/Hr
- Independent built-in 1A (FPO75) Charger for sealed lead acid or gel type batteries
- Microprocessor dual rate charging of 12 or 24V battery sets
- Automatic switchover to standby battery when AC fails
- Zero voltage drop when switched over to battery backup
Regulatory Compliance:
- UL294, UL603, UL864, UL1076, UL1481, UL2044, UL2572, ULC S318, ULC S319, ULC S527, CSA C22.2 #107.1, FCC Part 15, CSFM Approved
- (1) LP4502, (1) MR52-S3
- 4 Readers | 16 Inputs | 10 Outputs
- 20.00”H x 16.00”W x 4.50”D | 27 lbs.
Recommended board layout

Kit Includes
MFG Part # | BluBØX Order # | QTY | Description |
---|---|---|---|
LP4502 | 120-1301 | 1 | Mercury LP4502: Two door DB controller Ethernet 12/24VDC Auxiliary I/O |
MR52-S3 | 120-2501 | 1 | Mercury MR52-S3: Two door controller & auxiliary I/O 12/24VDC |
E2M-SK-2 | 577-3000 | 1 | BluBØX E2M-SK-2 Speed Kit: Two board precut DC power and RS485 wiring kit |
FPO75-E2M | 670-1320 | 1 | LifeSafety Power: single voltage power supply, includes enclosure |
Ordering Information
BluBØX Order # | Description |
---|---|
750-4601 | Mercury LP4502 Four Reader/Sixteen Input/Ten Output System for Four Doors |